CP-300系列 数字式功率表 

 

Specification  
Line measure 电源测量 Single phase, two conductor (1φ2W)
Values measured 测量值种类 Voltage, current, Active power, power factor, reactive power, apparent power, frequency.

Measurement ranges 测量范围

 

Voltage, current and active power see separate table of ranges and resolution.
Frequency: 10Hz~100KHz.

Operating principle 操作方式 Voltage and current: True RMS Power:Analog multiplier circuit.
Range selection 范围选择 Auto or manual (remote via RS-232)
Sampling rate 取样频率 3.3 times/sec.

Input impedance 输入阻抗

 

Voltage: approx 1Mohm
Current: approx 10mohm(CP-310,CP-320A) / approx 5mohm(CP-350

Maximum allowable input ****允许输入

Voltage: 650V rms, Current:20A RMS 50A peak(CP-310,CP-320A) / 50A RMS 125A peak (CP-350)

Maximum common mode voltage ****一般模式电压

Voltage and current input terminals: 600V rms.
Crest factor 波形因素 3

Input method 输入方法

 

Voltage: resistance divider
Current: shunt.

Input terminals 输入端子 large binding posts.
Effective input range 输入范围效率 5% to 100% of the set range.
Temperature Coefficient:  Less than ± 0.05% f.s/ oC.
Averaging function: Displays computed average (fix 3 measured).

 

Computing Function
Apparent Power Reactive power Power factor
VA = V*A VAR = √(VA2 -W2)  PF = W (VA)
Computing Range     :VA , VAR : Voltage and current range 

PF    : Zero to unity leading or lagging

Computing Accuracy: VA * VAR ± 0.05% of rated value 

PF    :± 0.001

 
Frequency measurement function
Operating Principle 操作方式 Reciprocal counting method
Measurement range 测量范围 5% to 100% set range(10Hz ~ 100KHz)
Auto Range 自动选择范围 45Hz / 10KHz / 100KHz
Accuracy 准确度 ±1 DGT of the range
Measurement Cycle 测量周期 3.3 times / sec
Display Range 表示范围 10.00Hz ~ 99999Hz(5 digits)
   
Interface
RS-232 Baud Rate:1200 , 2400 , 9600 bps.
  Transmission system : Srart-stop synchronization 8 bits , 1 stop bit. none parity
   
General specification
Dielectric Strength 耐压 2.2KV AC (50/60Hz) for one minute between input terminals and case.
Insulation Resistance 绝缘 more than 20Mohm at 500V dc between input terminals and case between case and power line.
Operating Temperature 操作温度 5 to 50 oC (41 to 104℉)
Humidity Range 操作湿度 10 to 90% (relative humidity) non-condensing.
Line Requirements 电源 AC115V or 230V ± 15%, 47 to 63 Hz 15VA
Dimensions/Weight 尺寸重量 260x110x360(WxHxD)/4.8Kgs net. 装箱材积表

 